{"id":18326,"date":"2026-01-05T15:00:16","date_gmt":"2026-01-05T14:00:16","guid":{"rendered":"https:\/\/conec.dckc.de\/novinky\/m8x1-2-3-leds-d\/"},"modified":"2026-01-05T16:56:27","modified_gmt":"2026-01-05T15:56:27","slug":"m8x1-2-3-leds-cz","status":"publish","type":"post","link":"https:\/\/conec.dckc.de\/cs\/novinky\/m8x1-2-3-leds-cz\/","title":{"rendered":"Konektory M8x1 pro senzory se 2 a 3 LED diodami"},"content":{"rendered":"<h5>&#8230; Spolehliv\u00e9 zobrazen\u00ed stavu p\u0159\u00edmo na konektoru \u2013 pro maxim\u00e1ln\u00ed provozn\u00ed spolehlivost<\/h5>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-19196\" src=\"https:\/\/conec.dckc.de\/wp-content\/uploads\/2026\/01\/LOGO-CA-PdJ-2026-nominee-230x300.png\" alt=\"\" width=\"155\" height=\"202\" srcset=\"https:\/\/conec.dckc.de\/wp-content\/uploads\/2026\/01\/LOGO-CA-PdJ-2026-nominee-230x300.png 230w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2026\/01\/LOGO-CA-PdJ-2026-nominee-785x1024.png 785w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2026\/01\/LOGO-CA-PdJ-2026-nominee-768x1002.png 768w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2026\/01\/LOGO-CA-PdJ-2026-nominee-1177x1536.png 1177w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2026\/01\/LOGO-CA-PdJ-2026-nominee-192x250.png 192w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2026\/01\/LOGO-CA-PdJ-2026-nominee-307x400.png 307w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2026\/01\/LOGO-CA-PdJ-2026-nominee-345x450.png 345w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2026\/01\/LOGO-CA-PdJ-2026-nominee-598x780.png 598w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2026\/01\/LOGO-CA-PdJ-2026-nominee.png 1358w\" sizes=\"(max-width: 155px) 100vw, 155px\" \/><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-18131 size-full\" src=\"https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/Titelbild_M8_2_3_LED_WEb80_GB.jpg\" alt=\"M8 senbsor connectors wirth 2 or 3 LED\u00b4s\" width=\"851\" height=\"315\" srcset=\"https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/Titelbild_M8_2_3_LED_WEb80_GB.jpg 851w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/Titelbild_M8_2_3_LED_WEb80_GB-300x111.jpg 300w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/Titelbild_M8_2_3_LED_WEb80_GB-768x284.jpg 768w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/Titelbild_M8_2_3_LED_WEb80_GB-275x102.jpg 275w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/Titelbild_M8_2_3_LED_WEb80_GB-375x139.jpg 375w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/Titelbild_M8_2_3_LED_WEb80_GB-475x176.jpg 475w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/Titelbild_M8_2_3_LED_WEb80_GB-570x211.jpg 570w\" sizes=\"(max-width: 851px) 100vw, 851px\" \/><\/p>\n<p>Konektory CONEC M8x1 se 2 nebo 3 integrovan\u00fdmi LED diodami se ide\u00e1ln\u011b hod\u00ed pro kabel\u00e1\u017e senzor\u016f\/aktu\u00e1tor\u016f v automatizaci v\u00fdroby, stroj\u00edrenstv\u00ed a strojn\u00ed v\u00fdrob\u011b, dopravn\u00edkov\u00e9 a balic\u00ed technice, jako\u017e i ve zku\u0161ebn\u00edch a kontroln\u00edch syst\u00e9mech. Pou\u017e\u00edvaj\u00ed se v\u0161ude tam, kde je vy\u017eadov\u00e1na kompaktn\u00ed konstrukce, vysok\u00e1 spolehlivost a rychl\u00e1 diagnostika. Tyto kompaktn\u00ed konektory jsou k dispozici v p\u0159\u00edm\u00e9m i \u0161ikm\u00e9m proveden\u00ed \u2013 bu\u010f jako jednostrann\u00e9, nebo jako propojovac\u00ed kabely. Zaji\u0161\u0165uj\u00ed spolehliv\u00fd p\u0159enos sign\u00e1lu s vizu\u00e1ln\u00ed kontrolou stavu p\u0159\u00edmo v m\u00edst\u011b p\u0159ipojen\u00ed.<\/p>\n<p>V z\u00e1vislosti na verzi jsou konektory vybaveny dv\u011bma nebo t\u0159emi integrovan\u00fdmi LED diodami, kter\u00e9 indikuj\u00ed stav nap\u00e1jen\u00ed, sign\u00e1lu nebo sp\u00ednac\u00edho stavu. Tato vizu\u00e1ln\u00ed zp\u011btn\u00e1 vazba umo\u017e\u0148uje rychl\u00e9 uveden\u00ed do provozu, zjednodu\u0161uje \u00fadr\u017ebu a zkracuje prostoje d\u00edky c\u00edlen\u00e9 diagnostice poruch \u2013 p\u0159\u00edmo na spoji.<\/p>\n<p>Pro optim\u00e1ln\u00ed p\u0159izp\u016fsoben\u00ed konstruk\u010dn\u00edm podm\u00ednk\u00e1m jsou konektory k dispozici v rovn\u00e9m i \u0161ikm\u00e9m proveden\u00ed. P\u0159ekryt\u00ed zaji\u0161\u0165uje kryt\u00ed IP67, co\u017e zaru\u010duje spolehliv\u00fd provoz i v n\u00e1ro\u010dn\u00fdch pr\u016fmyslov\u00fdch podm\u00ednk\u00e1ch. M\u016f\u017eete si vybrat mezi robustn\u00edm kabelem z PVC nebo kabelem z TPU bez obsahu halogen\u016f. Konektory jsou k dispozici ve standardizovan\u00fdch d\u00e9lk\u00e1ch kabel\u016f \u2013 na vy\u017e\u00e1d\u00e1n\u00ed jsou k dispozici vlastn\u00ed konfigurace.<\/p>\n<p>Konektory M8x1 spole\u010dnosti CONEC s integrovan\u00fdmi LED indik\u00e1tory stavu nab\u00edzej\u00ed skute\u010dnou p\u0159idanou hodnotu v mnoha pr\u016fmyslov\u00fdch odv\u011btv\u00edch.<br \/>\nV intralogistick\u00fdch a dopravn\u00edkov\u00fdch syst\u00e9mech umo\u017e\u0148uj\u00ed spolehliv\u00e9 p\u0159ipojen\u00ed sv\u011bteln\u00fdch z\u00e1vor, sn\u00edma\u010d\u016f p\u0159ibl\u00ed\u017een\u00ed a pohon\u016f na dopravn\u00edkov\u00fdch p\u00e1sech. Z\u00e1rove\u0148 podporuj\u00ed monitorov\u00e1n\u00ed a \u0159\u00edzen\u00ed materi\u00e1lov\u00fdch tok\u016f v automatizovan\u00fdch skladov\u00fdch syst\u00e9mech \u2013 s jasnou zp\u011btnou vazbou LED o stavu sign\u00e1lu p\u0159\u00edmo na spoji.<br \/>\nV balic\u00edch a plnic\u00edch syst\u00e9mech zaji\u0161\u0165uj\u00ed konektory efektivitu: lze bezpe\u010dn\u011b p\u0159ipojit koncov\u00e9 sp\u00edna\u010de, sn\u00edma\u010de hladiny a teplotn\u00ed sondy, zat\u00edmco integrovan\u00fd displej LED umo\u017e\u0148uje vizu\u00e1ln\u00ed sledov\u00e1n\u00ed sp\u00ednac\u00edch sign\u00e1l\u016f b\u011bhem provozu \u2013 bez nutnosti pou\u017eit\u00ed dal\u0161\u00edch diagnostick\u00fdch za\u0159\u00edzen\u00ed.<br \/>\nV testovac\u00edch a kontroln\u00edch syst\u00e9mech nab\u00edzej\u00ed konektory flexibiln\u00ed p\u0159ipojen\u00ed s okam\u017eit\u011b viditelnou kontinuitou sign\u00e1lu \u2013 ide\u00e1ln\u00ed pro prototypy, laboratorn\u00ed prost\u0159ed\u00ed nebo do\u010dasn\u00e9 instalace, kde je nezbytn\u00e1 rychl\u00e1 kontrola a nastaven\u00ed.<\/p>\n<p>Z\u00e1v\u011br:<br \/>\nKonektory M8x1 s LED indik\u00e1tory jsou v\u00edce ne\u017e jen propojovac\u00ed prvky \u2013 jsou to inteligentn\u00ed diagnostick\u00e9 n\u00e1stroje pro n\u00e1ro\u010dn\u00e9 oblasti pou\u017eit\u00ed.<\/p>\n<h3>V\u00fdhody:<\/h3>\n<ul>\n<li>Kompaktn\u00ed design<\/li>\n<li>P\u0159\u00edm\u00e9 zobrazen\u00ed stav\u016f sign\u00e1lu<\/li>\n<li>Stupe\u0148 kryt\u00ed IP67<\/li>\n<li>Jednoduch\u00e1 mont\u00e1\u017e<\/li>\n<li>K dispozici jsou varianty kompatibiln\u00ed s hnac\u00edmi \u0159et\u011bzci<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Oblasti pou\u017eit\u00ed:<\/h3>\n<ul>\n<li>Intralogistika a dopravn\u00edkov\u00e9 technologie<\/li>\n<li>Balic\u00ed a plnic\u00ed syst\u00e9my<\/li>\n<li>Technologie budov a bezpe\u010dnostn\u00ed syst\u00e9my<\/li>\n<li>Testovac\u00ed a kontroln\u00ed syst\u00e9my<\/li>\n<li>Sol\u00e1rn\u00ed technologie a technologie m\u011b\u0159en\u00ed \u017eivotn\u00edho prost\u0159ed\u00ed<\/li>\n<\/ul>\n<p><a class=\"button first\" href=\"https:\/\/conec.dckc.de\/catalog\/en\/circular-connectors-sensor-actor-line\/overmoulded.html?_=1751287216875&amp;a00013=5622&amp;a00016=5679%2C5680&amp;id=254\"><strong>Od spole\u010dnosti PRODUKTBEREICH<\/strong><\/a><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-18120\" src=\"https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/M8_2_3_LED_mit-Applikationen_WEb80.jpg\" alt=\"ZUverl\u00e4ssige Statusanzeige direkt am M8x1 Steckverbinder\" width=\"851\" height=\"137\" srcset=\"https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/M8_2_3_LED_mit-Applikationen_WEb80.jpg 2480w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/M8_2_3_LED_mit-Applikationen_WEb80-300x48.jpg 300w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/M8_2_3_LED_mit-Applikationen_WEb80-1024x165.jpg 1024w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/M8_2_3_LED_mit-Applikationen_WEb80-768x124.jpg 768w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/M8_2_3_LED_mit-Applikationen_WEb80-1536x247.jpg 1536w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/M8_2_3_LED_mit-Applikationen_WEb80-2048x329.jpg 2048w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/M8_2_3_LED_mit-Applikationen_WEb80-275x44.jpg 275w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/M8_2_3_LED_mit-Applikationen_WEb80-375x60.jpg 375w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/M8_2_3_LED_mit-Applikationen_WEb80-475x76.jpg 475w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/M8_2_3_LED_mit-Applikationen_WEb80-570x92.jpg 570w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2025\/06\/M8_2_3_LED_mit-Applikationen_WEb80-1160x187.jpg 1160w\" sizes=\"(max-width: 851px) 100vw, 851px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>&#8230; Spolehliv\u00e9 zobrazen\u00ed stavu p\u0159\u00edmo na konektoru \u2013 pro maxim\u00e1ln\u00ed provozn\u00ed spolehlivost Konektory CONEC M8x1 &#8230;<\/p>\n","protected":false},"author":2,"featured_media":19192,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[63],"tags":[],"class_list":["post-18326","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-novinky"],"acf":[],"_links":{"self":[{"href":"https:\/\/conec.dckc.de\/cs\/wp-json\/wp\/v2\/posts\/18326","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/conec.dckc.de\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/conec.dckc.de\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/conec.dckc.de\/cs\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/conec.dckc.de\/cs\/wp-json\/wp\/v2\/comments?post=18326"}],"version-history":[{"count":3,"href":"https:\/\/conec.dckc.de\/cs\/wp-json\/wp\/v2\/posts\/18326\/revisions"}],"predecessor-version":[{"id":19207,"href":"https:\/\/conec.dckc.de\/cs\/wp-json\/wp\/v2\/posts\/18326\/revisions\/19207"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/conec.dckc.de\/cs\/wp-json\/wp\/v2\/media\/19192"}],"wp:attachment":[{"href":"https:\/\/conec.dckc.de\/cs\/wp-json\/wp\/v2\/media?parent=18326"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/conec.dckc.de\/cs\/wp-json\/wp\/v2\/categories?post=18326"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/conec.dckc.de\/cs\/wp-json\/wp\/v2\/tags?post=18326"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}