{"id":12288,"date":"2019-02-22T17:38:17","date_gmt":"2019-02-22T16:38:17","guid":{"rendered":"https:\/\/conec.dckc.de\/?p=12288"},"modified":"2024-10-29T14:48:21","modified_gmt":"2024-10-29T13:48:21","slug":"conec-ip67-power-bayonet-connectors","status":"publish","type":"post","link":"https:\/\/conec.dckc.de\/en\/news-en\/conec-ip67-power-bayonet-connectors\/","title":{"rendered":"CONEC IP67 Power Bayonet Connectors"},"content":{"rendered":"<h5>&#8230; DESIGNED FOR INDUSTRIAL CABLE CONNECTIONS IN HARSH INVIRONMENTS<\/h5>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12269\" src=\"https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/PowerBajoentt-mit-Applikationen_Web80-1024x165-1.jpg\" alt=\"\" width=\"1024\" height=\"165\" srcset=\"https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/PowerBajoentt-mit-Applikationen_Web80-1024x165-1.jpg 1024w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/PowerBajoentt-mit-Applikationen_Web80-1024x165-1-300x48.jpg 300w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/PowerBajoentt-mit-Applikationen_Web80-1024x165-1-768x124.jpg 768w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/PowerBajoentt-mit-Applikationen_Web80-1024x165-1-275x44.jpg 275w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/PowerBajoentt-mit-Applikationen_Web80-1024x165-1-375x60.jpg 375w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/PowerBajoentt-mit-Applikationen_Web80-1024x165-1-475x77.jpg 475w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/PowerBajoentt-mit-Applikationen_Web80-1024x165-1-570x92.jpg 570w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p>CONEC has extended its range of IP67 connectors with bayonet locking by a new power connector variant in addition to data and bus connectors.<\/p>\n<p>The connector series is designed for industrial cable connections with IP67 protection and the bayonet locking allows a quick, simple and robust connection in harsh environments.<\/p>\n<p>A 2- and 3-pos. version is available within the IP67 power bayonet connector series. The 2-pos. version is mainly designed for DC use up to max. 48 V DC and the 3-pos. version utilizes a premating contact for AC up to max. 250 V AC with protective earth contact (PE).<\/p>\n<p>The contacts are designed as crimp variants for wire cross sections from AWG 12 to AWG 10 and optionally AWG 10 to AWG 8 for the 2-pos. and also from AWG 14 to AWG 12 for the 3-pos. version. The crimp connection allows for easy, safe and quick mounting of the contacts that are included in the connector kit.<\/p>\n<p>Shape and panel cut-outs have been made according to the existing IP67 series for RJ45, USB 2.0 and Fiber Optic LC<br \/>\nDuplex which allows a flexible use of different connector versions within one system.<\/p>\n<p>&nbsp;<\/p>\n<p>Productdetails:<\/p>\n<h3>Benefits:<\/h3>\n<ul>\n<li>Easy and safe locking by bayonet lock<\/li>\n<li>High current carrying capability<\/li>\n<li>Cable to cable connection<\/li>\n<li>Cable to receptacle connection<\/li>\n<li>Protective cap with tether available<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Fields of application:<\/h3>\n<ul>\n<li>Automation systems<\/li>\n<li>Industrial process control<\/li>\n<li>Communications equipment<\/li>\n<li>Diagnostic equipment<\/li>\n<li>Outdoor telecommunications systems<\/li>\n<li>Use in harsh environments<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n\n<table id=\"tablepress-45\" class=\"tablepress tablepress-id-45\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">No. of poles<\/th><th class=\"column-2\">Gender<\/th><th class=\"column-3\">Current rating<\/th><th class=\"column-4\">Working voltage<\/th><th class=\"column-5\">Temperature range<\/th><th class=\"column-6\">Suitable for cable sizes<\/th><th class=\"column-7\">Degree of protection in mated condition<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">2-pos.<\/td><td class=\"column-2\">Male, female<\/td><td class=\"column-3\">30 A<\/td><td class=\"column-4\">48 V AC\/DC<\/td><td class=\"column-5\">-40\u00b0C to +100\u00b0C<\/td><td class=\"column-6\">AWG 8* \u2013 10<br \/>\nAWG 10 -12<\/td><td class=\"column-7\">IP67<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">3-pos. (2+PE)<\/td><td class=\"column-2\">Male, female<\/td><td class=\"column-3\">20 A<\/td><td class=\"column-4\">250 V AC\/DC<\/td><td class=\"column-5\">-40\u00b0C to +100\u00b0C<\/td><td class=\"column-6\">AWG 12 \u2013 14<\/td><td class=\"column-7\">IP67<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">* For AWG 8 stranded 19\/21, 37\/24 and 65\/26 wire only<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td><td class=\"column-4\"><\/td><td class=\"column-5\"><\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-45 from cache -->\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12275\" src=\"https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/Pressebild_schmal_WEb80-1024x454-1.jpg\" alt=\"\" width=\"1024\" height=\"454\" srcset=\"https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/Pressebild_schmal_WEb80-1024x454-1.jpg 1024w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/Pressebild_schmal_WEb80-1024x454-1-300x133.jpg 300w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/Pressebild_schmal_WEb80-1024x454-1-768x341.jpg 768w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/Pressebild_schmal_WEb80-1024x454-1-275x122.jpg 275w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/Pressebild_schmal_WEb80-1024x454-1-375x166.jpg 375w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/Pressebild_schmal_WEb80-1024x454-1-475x211.jpg 475w, https:\/\/conec.dckc.de\/wp-content\/uploads\/2019\/02\/Pressebild_schmal_WEb80-1024x454-1-570x253.jpg 570w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>&#8230; DESIGNED FOR INDUSTRIAL CABLE CONNECTIONS IN HARSH INVIRONMENTS CONEC has extended its range of &#8230;<\/p>\n","protected":false},"author":1,"featured_media":10998,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[62],"tags":[],"class_list":["post-12288","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/conec.dckc.de\/en\/wp-json\/wp\/v2\/posts\/12288","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/conec.dckc.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/conec.dckc.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/conec.dckc.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/conec.dckc.de\/en\/wp-json\/wp\/v2\/comments?post=12288"}],"version-history":[{"count":2,"href":"https:\/\/conec.dckc.de\/en\/wp-json\/wp\/v2\/posts\/12288\/revisions"}],"predecessor-version":[{"id":16482,"href":"https:\/\/conec.dckc.de\/en\/wp-json\/wp\/v2\/posts\/12288\/revisions\/16482"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/conec.dckc.de\/en\/wp-json\/wp\/v2\/media\/10998"}],"wp:attachment":[{"href":"https:\/\/conec.dckc.de\/en\/wp-json\/wp\/v2\/media?parent=12288"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/conec.dckc.de\/en\/wp-json\/wp\/v2\/categories?post=12288"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/conec.dckc.de\/en\/wp-json\/wp\/v2\/tags?post=12288"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}